| Name of Flowmeter | K100 Coriolis Mass Flow Meters |
|---|---|
| Flange Compatibility | DN25/DN32/DN40 |
| Flow Range | 1.08-21.6t/h |
| Grade of Accuracy | ±0.1%; ±0.15%; ±0.2% |
| Turndown | 20:1 |
| Zero Stability | 0.76 kg/h |
| Density Range | 0.2 ~ 2.0 kg/cm³ |
| Density Error | ± 0.0005g/cm³ |
| Temperature Range | -240℃~ +260℃ |
| Temperature Error | ± 0.2℃ |
| Explosion-proof Grade | Sensor: Ex ib IIC T1- T6 Gb |
| Transmitter: Ex d [ib] IIC T6 Gb | |
| Protection Class | IP66/IP67 |
| IP66/IP67 | |
| Outline Dimensions | (212~216) *106*412 mm |
K100 Mass Flow Meter Dimensions (Separate Type)

Unit: mm
| Model | Flange Compatibility | A (Customizable) | B | C | D | E |
|---|---|---|---|---|---|---|
| K100 | DN25/DN32/DN40 | 206~210 | 412 | 568 | 106 | 540 |
K100 Mass Flow Meter Dimensions (Integral Type)

Unit: mm
| Model | Flange Compatibility | A (Customizable) | B | C | D | E | F |
|---|---|---|---|---|---|---|---|
| K100 | DN25/DN32/DN40 | 206~210 | 412 | 568 | 106 | 698 | 174 |